| Microtector II G450 4 gas detector
This robust 4-Gas detector measures up to 4 gases simultaneously: Oxygen (O2), hydrogen sulphide (H2S), carbon monoxide (CO) and combustible gases (CH4). It was developed especially for personal protection against gas hazards and is carried at the working clothes. A large, coloured graphic display provides clear readings of all data. The display can be turned 180° by just pushing a button ??" this allows the display to be read easily even if the detector is carried at the belt. The zoom function allows an easy reading of single measuring values and shows additional information on the selected gas. Hands free for maximum safety. Gfg offer an industry leading 3 year guarantee on their O2 sensors
- Small, light and reliable
- For oxygen (O2), hydrogen sulphide (H2S), carbon monoxide (CO) and combustible gases (CH4)
- Innovative visual alarm system with colour change of display and bright flashing LED
- Extremly loud alarm 103 dB(A) for optimal personal protection
- Flip-flop display with zoom function
- Long operational time up to 30 hours
- Robust watertight housing (IP67)
- Attachable motorized pump with its own independent power supply (optional)
- Dockingstation for quick and easy bump test and adjustment, charging and documentation (optional)
The loop data logger records gas concentrations and alarms over a period of up to 50 hours. This data can be transferred to a PC to be displayed and evaluated. The data logger has a storage capacity of 1800 measuring points per gas. Storing intervals and mode (average, peak, instantaneous values) are programmable individually.
Inaccessible areas, like tanks and containers, can contain lethal gas mixtures. With the G400-MP1 an attachable high-performance pump is available that can sample the gas from up to 100 metres away. The pump and tube is attached easily, and its own power supply does not affect the operational time of the instrument. Either a rechargeable NiMH battery pack or alkaline batteries are available.
Power supply is provided by either a rechargeable NiMH battery pack or Alkaline batteries. Depending on alarm frequency and alarm duration the operational time is up to 30 hours. A NiMH battery pack with Ex-proof LED allow a built in torch option. The NiMH batteries can be fully recharged in less than 4 hours with the drop-in charger (optional). Additional charging options are smart charger cap, dockingstation or vehicle charger.
The innovative Dockingstation DC400 is a complete device management system, that offers the user reduced cost and time for performing functional tests (Bump tests), calibration and documentation. The DS400 is compact, portable and does not require a PC to operate.
When inserted into the DS400, the detector is automatically bump checked. Alarm functions are tested to ensure correct operation, in addition to sensor response. Calibration reports can be printed out from the DS400 (via PC). All data is recorded on a memory card, and the data transferred from the detector to the DS400. The data can then be transferred to PC via a USB cable and manipulated directly in Excel.
The DS400 uses simple traffic light indicators for the user to give the detector status ??" green is go, red is stop. The DS400 ensures that your detectors are always ready to go, in a safe condition and at a minimum cost.
Download Brochure
|
|
| |
| Microtector II G460 7 gas detector
This light and robust gas detector is the development of the proven Microtector II G450. The key features are retained - smart, interchangeable sensor technology, low cost of ownership - but extra functionality is now added.
The Microtector II G460 measures up to 7 gases simultaneously in ambient air for increased workplace safety. The sensor slots can be equipped individually. Different detection principles are available for optimal measuring results.
Measurable gases The most common sensors detect O2, H2S, CO, CO2 and combustible gases. Additional sensors are available for NH3, HCl, PH3, HCN, NO, NO2, SO2 and a variety of other gases.
CO2 - reliable infrared measurement For increasing the user's safety, the Microtector II G460 detects carbon dioxide by means of a selective infrared sensor (NDIR). This sensor provides long-term stable detection values. Unlike electrochemical sensors, IR technology is not subject to cross sensitivity from toxic hydrogen sulphide.
The Microtector II G460 is the smallest detector world-wide which can be equipped with both an infrared sensor and a PID.
Monitoring for toxic volatile organic compounds (VOC) Photoionization detector (PID) equipped instruments are increasingly viewed as the best choice for measurement of VOCs at exposure limit concentrations. Familiar substances containing VOCs include solvents, paint thinner and nail polish remover, as well as the vapors associated with fuels such as gasoline, diesel, heating oil, kerosene and jet fuel. The category also includes many specific toxic substances such as benzene, butadiene, hexane, toluene, xylene, and many others. Most VOC vapors are flammable at surprisingly low concentrations. For most VOCs, however, the toxic exposure limit is exceeded long before readings reach a concentration high enough to trigger a combustible range alarm.
Additional functions of the Microtector II G460
- IR-Sensor (CO2) for long-term stable detection values
- Poison resistant CO2 sensor
- PID for monitoring toxic volatile organic compounds (VOC)
- Smart senso technology for adaption and easy replacement
Datalogger (optional) The loop data logger records gas concentrations and alarms over a period ofup to 50 hours. This data can be transferred to a PC to be displayed and evaluated. The data logger has a storage capacity of 1800 measuring points per gas. Storing intervals and mode (average, peak, instantaneous values) are programmable individually.
Attachable motorized pump (optional) Inaccessible areas, like tanks and containers, can contain lethal gas mixtures. With the G400-MP1 an attachable high-performance pump is available that can sample the gas from up to 100 metres away. The pump and tube is attached easily and has its own power supply does not affect the operational time of the instrument. Either a rechargeable NiMH battery pack or alkaline batteries are available.
Power supply options Power supply is provided by either a rechargeable NiMH battery pack or Alkaline batteries. Depending on alarm frequency and alarm duration the operational time is up to 30 hours. A NiMH battery pack with Ex-proof LEDs allow a built-in torch option. The NiMH batteries can be fully recharged in less than 4 hours with the drop-in charger. Additional charging options are smart charger cap, dockingstation or vehicle charger.
Carrying possibilities (optional) The light detector can be securely fastened at the user's clothing with a durable crocodile clip. A belt clip is also available. The reversible display allows easy reading by the user.
Comprehensive accessories Various options allow individual adaptation to personal requirements. A number of accesssories make the Microtector II G460 a complete, useful instrument in everyday work with combustible and toxic gases.
The innovative Dockingstation DS400 is a complete device management system, that offers the user reduced cost and time for performing functional tests (Bump tests), calibration and documentation. The DS400 is compact, portable and does not require a PC to operate.
When inserted into the DS400, the detector is automatically bump checked. Alarm functions are tested to ensure correct operation, in addition to sensor response. Calibration reports can be printed out from the DS400 (via PC). All data is recorded on a memory card, and the data transferred from the detector to the DS400. The data can then be transferred to PC via a USB cable and manipulated directly in Excel.
The DS400 uses simple traffic light indicators for the user to give the detector status - green is go, red is stop. The DS400 ensures that your detectors are always ready to go, in a safe condition and at a minimum cost.
Download brochure |
|
| |
| MICRO IV single gas detector
Single-gas detector with data-logger The Micro IV single-gas detector is the successor to the proven Micro III. The key features of the Micro III are retained - smart, interchangeable sensor technology, low cost of ownership where 1 x AA battery lasts for up to 6 months in continuous use - but extra functionality is now added.
The Micro IV contains an integrated data-logger which records and time-stamps all events. This stored data can be transmitted to a PC via either the DI220 data interface station or DS220 docking station. Three alarm levels are available (most competing instruments only offer two) in addition to STEL and TWA alarms. The Micro IV has a very loud (95dB) sounder and high-visibility red LED alarms. Vibration alarm is also available as an option. A large display ensures that gas concentrations can be quickly and easily read by the user.
Gases available: O2, H2S, CO, NO, NH3, HCN, HCl, SO2, H2, C2H4O, SiH4, PH3, THT, HF, COCl2, NO2, Cl2, O3, ClO2
Additional functionality of the MICRO IV
- Data-logging
- Infrared interface for data communication to Dockingstations
- Continuous storage of data without PC
- Continuous display of gas concentration
- Up to 6 months continuous operation with only one AA battery
- Simple bump check and calibration via the Dockingstation (option)
Carrying possibilities (option) The Micro IV is compact, light and can be securely fastened to the user's clothing with a durable crocodile clip. A belt clip is also available. An optional rubber boot is also available to give the instrument further protection in arduous work environments.
Attachable Motorised Pump (accessories) Inaccessible areas, like tanks and containers, can contain deadly gas mixtures. With the Micro IV, and attachable high-performance pump is available that can sample the gas from up to 30 metres away.
The pump and tube is quick and easy to attach, and has its' own power supply which means the run time of the Micro IV instrument is not compromised. The separate AA battery pack gives 8 hours of continuous pump operation.
The innovative Dockingstation DS200 is a complete device management system, that offers the user reduced cost and time for performing functional tests (Bump tests), calibration and documentation. The DS200 is compact, portable and does not require a PC to operate.
When inserted into the DS200, the detector is automatically bump checked. Alarm functions are tested to ensure correct operation, in addition to sensor response. Calibration reports can be printed out from the DS200 (via PC).
All data is recorded on a memory card, and the data transferred from the detector to the DS200 via IR link. The data can then be transferred to PC via a USB cable and manipulated directly in Excel.
The DS200 uses simple traffic light indicators for the user to give the detector status - green is go, red is stop. The DS220 ensures that your detectors are always ready to go, in a safe condition and at a minimum cost.
Red Test failed Yellow Test in process Green Test successfully completed and detector ready for use!
The MICRO IV Data Interface DI220 is a simple device management system providing fast configuration and simple data download. Stored data can then be transferred from the instrument to PC via a USB cable and manipulated directly in Excel.
Download Brochure |
| |
|
|
|
Baseline Mocon 8900 Analyser for single or multi-point monitoring of Hydrocarbons
|
The Baseline® Series 8900 is a multi-purpose gas chromatograph designed to continuously monitor single or multiple gas components in a wide range of applications.
The analyzer is microprocessor based and contains powerful embedded firmware. This makes it an online instrument with GC technology that is virtually transparent to the end user. There are a variety of state of the art detector, calibration and gas train options offering the flexibility and precision necessary to analyze from sub-parts per billion (sub-ppb) to percent levels.
The 8900's automatic calibration is ideal for unattended operation. It can be set up on a bench-top or rack-mounted, and its compact size makes it transportable. There are a variety of industry standard outputs, such as network (LAN), RS232, multiple 4-20 mA or 0-20 mA, and multiple relays for concentration alarms, diagnostics or user specified timed events.
Gas chromatography applications are configured at the factory before delivery by running the SkyChrom™ software from Baseline®. The computer can be disconnected and the analyzer will operate independently. When connected to SkyChrom™, data can be collected in a universal text format with a user definable data export utility for custom reports. Chromatograms can be stored continuously or based on events such as alarms. Detector options include Photoionization Detector (PID), Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD).
|
|
Well logging-fast C1-C5
Area monitoring of toxic gases for industrial hygiene and safety - Ethylene Oxide, Acrylonitrile, Butadiene, Styrene, Epichlorohydrin and many others
Fenceline (perimeter) monitoring around industrial and remediation sites - BTEX and other VOC's
Scrubber efficiency - hydrocarbons and VOC's
Carbon bed breakthrough detection -solvents and organic compounds
Quality Assurance Monitoring, contaminant analysis or blending of industrial gases
Methane/Non-methane analysis
A list of over 200 detectable gases is available upon request
|
|
Accurate & specific to a wide variety and range of gases
Continuous unattended operation, operates with or without a computer
Automatic calibration and baseline correction for long-term stability
Outputs include digital, user definable analog and user definable logic
PC based SkyChrom™ software stores multiple analytical methods and chromatograms
Multipoint sampling options
Onboard short-term data storage
| | | | |
 |
|
Some of the measured gases measured include:
Acrylonitrile BTEX C1-C5 Hydrocarbons Ethylene Oxide Hydrogen Sulphide and Carbon Disulphide in Air Formaldehyde Methane, Methanol, Ethanol Naphthalene Total Sulphur in CO2 or Air
Please contact us for any specific requirements you may have.
Download Brochure |
|
|
| |
| Fastest monitoring of flammable gases
Superior technology Wherever flammable gases or vapours are found, the CC28 provides the best solution for safe monitoring. ATEX-certified design, built-in EX-certified horn and bright LED lights allow safe operation within highly flammable areas. The gas alarm is transmitted to the central control panel, simultaneously warning the control room and the worker in the danger area.
Fastest detection available Using GfG's unique sensor technology, coupled with a special "chimney-effect" the CC28 transmitter has the shortest response time in the market, detecting flammable gases using catalytic bead technology.When used in conjunction with our GMA controller series, a programmed delta alarm can shorten the response time still further. This gives an extra level of safety when handling explosive gas risks.
Smart sensor technology Installation and sensor exchange are quick and easy using pre-calibrated smart, plug-in sensors. One-man calibration/ adjustment is possible directly at the transmitter, without opening the housing.
Versions for each application
CC28 basic unit
CC28 D with additional display of gas concentration
CC28 DA with additional bright LED lights and loud horn. The extra costs for installing an Ex-certified horn and audible alarm are omitted.
The advantages at a glance
- World-wide shortest response time
- Three choices - no display with display or with display and built-in audible and visual alarms
- ATEX-Certification
II 2G EEx dem [ib] IIC T4
- EEC design inspection certificate BVS 04 ATEX E 132 X, functional test: BVS 05 ATEX G 001 X
0158
- Ex-certified visual and loud acoustic alarm
- Less wiring required
- Simple sensor exchange using smart, plug-in sensors
- Long sensor lifetime
- Low maintenance costs
- Status and function display directly on the transmitter
- One-man calibration/ adjustment without opening casing
- Operation possible in inaccessible places via remote control (option)
Remote control (option) Some flammable gases are lighter than air (e.g. methane). If a transmitter is installed close to the ceiling, it can be connected by a fixed installed cable with a plug connection to the remote control. Thus, all adjustments can be made comfortably from floor level. With one remote control device, an unlimited number of transmitters can be controlled in this way.
Using transmitters without display, the remote control shows the current values on its' own display. The display of the remote control mimics the transmitter display exactly. Inspection, maintenance and adjustment are therefore greatly simplified. Using the remote control inspection, service and calibration can be performed easily by one person.
|
|
| |
| For toxic gases, oxygen and hydrogen
Superior technology Wherever gas hazards are to be found, the EC28 provides the best solution for safe monitoring. ATEX-certified design, built-in EX-certified horn and bright LED lights allow safe operation. The gas alarm is transmitted to the central control panel, simultaneously warning the control room and the worker in the danger area.
Smart sensor technology Installation and sensor exchange are quick and easy using pre-calibrated smart, plug-in sensors. One-man calibration/ adjustment is possible directly at the transmitter, without opening the housing.
Versions for each application
EC28 basic unit EC28 D with additional display of gas concentration EC28 DA with additional bright LED lights and loud horn. The extra costs for installing an EX-certified horn and audible alarm are omitted EC28 DAR with additional external alarm relay EC28 B with additional bus connection EC28 DB with additional display of gas concentration EC28 DAB with additional bright LED lights and loud horn. The extra costs for installing an EX-certified horn and audible alarm are omitted EC28 i intrinsically safe version EC28 Di instrinsically safe, with additional display of gas concentration
The advantages at a glance
- Three choices - no display with display or with display and built-in audible and visual alarms
- ATEX-Certification
II 1G EEx ia IIC T4/ II 2G EEx em [ib] IIC T4
- BVS 04 ATEX E 132 X / BVS 04 ATEX E 132 X
0158
- Ex-certified visual and loud acoustic alarm
- Less wiring required
- Simple sensor exchange using smart, plug-in sensors
- Long sensor lifetime
- Low maintenance costs
- Status and function display directly on the transmitter
- One-man calibration/ adjustment without opening casing
- Operation possible in inaccessible places via remote control (option)
Remote control (option) Some flammable gases are lighter than air (e.g. methane). If a transmitter is installed close to the ceiling, it can be connected by a fixed installed cable with a plug connection to the remote control. Thus, all adjustments can be made comfortably from floor level. With one remote control device, an unlimited number of transmitters can be controlled in this way.
Using transmitters without display, the remote control shows the current values on its' own display. The display of the remote control mimics the transmitter display exactly. Inspection, maintenance and adjustment are therefore greatly simplified. Using the remote control inspection, service and calibration can be performed easily by one person.
|
|
| |
| For toxic gases, hydrogen and oxygen
Complete transmitter and controller in one unit The GMA36 Pro is an intelligent and flexible measuring system, simply wall mounted. Toxic gases, oxygen and hydrogen are monitored continuously and reliably.
If the gas concentration exceeds a set threshold value, the system warns immediately via the integrated horn and LED lights. Additionally, alarm relays for external alarm devices or valves are provided. Configuration and calibration use simple menus accessed via the 3 keys on the front. Maintenance and operation are straightforward.
The AutoCal program ensures an automatic adjustment of the measuring signal to the test gas. The large display clearly shows the measured gas concentration, limit values exceeded and operating condition.
Measurable gases C2H4O, Cl2, ClO2, CO, COCl2, H2, HCl, HCN, H2S, HF, NH3, NO, NO2, CO2, O3, SiH4, SO2
Smart sensor technology The GMA36 Pro uses smart, plug-in electro-chemical sensors that can be easily exchanged without opening the housing. This saves time and money.
The advantages at a glance
- Loud, integrated horn
- Large illuminated LCD display
- Plug-in Smart sensors
- Scaleable measuring range
- Simple 3-key-operation
- Easy maintenance
- AutoCal for simple and fast calibration
- Housings with splash-water protection (IP54)
|
|
| |
|
The GMA300 system is a microprocessor-based, 19" rack mounted gas control system for all measuring functions. Depending on the transmitter type connected, the GMA300 is a complete gas detection system for detection of flammable and toxic hazards, and oxygen. The GMA300's highly flexible construction and variety of functions make the system suitable for all gas detection tasks. 3 alarm levels can be set. Additional relay and alarm functions can be configured. All transmitter types can be connected. GMA300 controllers support both 2- and 3-wire devices. The controller supplies power to the attached transmitters, depending on system configuration a large number of measuring points can be connected. In addition to the GMA100 system, the GMA300 offers digital communication via CAN OPEN bus.
GMA300 system versions
GMA301 for 1 transmitter for control of 1 measuring point. 3 alarms and fault output.
GMA304 for 4 transmitters for control of up to 4 measuring points. 3 common alarms and fault output.
Simple operation Gas concentration is continuously shown on a 3-digit LED display. Gas concentration, gas type and detection range can all be displayed via a simple button push. Zero and span adjustment can also be performed simply via the simple operation from push buttons. The controller has a min/max memory that enables the user to check the exact concentrations encountered after a gas alarm has occurred. In addition, the highest or lowest measured value is stored and displayed in the LED display. A 4-20mA output is available to transmit gas measurement readings to external devices.
Alarm functions 3 alarm thresholds can be set. Additional relay and alarm functions are adjustable: exceeding/falling below, latching/not latching, quiescent current/full load current, open/normally closed contact, signal delay and hysteresis. 4 LED lights display operation status, alarm and fault signals.
Delta alarm The delta alarm function can be used to ensure the fastest response to a gas leak. Not only the measured gas concentration is considered, but also the rate of rise of the measured value. An unusually fast rate of rise can be used to trigger the alarms, even before the normal threshold value has been reached.
The advantages at a glance
- Simple rack mounting
- Measured values and alarms are displayed on each channel
- Digital interface CAN OPEN bus
- Simple operation
- Menu-led service operation
- 4 relays for 3 alarms, 1 fault alarm
|
|
|
|
|