GM700 In-Situ gas analyser | EMS
GM700 In-Situ gas analyser

In-situ analyser for HCL,HF,NH3

High reliability and precision as well as minimal response times are the distinguishing features of the GM700 laser gas analyser. Based on the principle of TDLS (Tunable Diode Laser Spectroscopy) and by using specific light absorption, the GM700 is able to measure several gas components, such as NH3, HF, HCl or H2O. The in-situ measurement is ideal for the fast determination of gas concentrations in process control and emission monitoring.
Measured valuesNH3, HF, HCl, H2O
Performance-tested measuredHF
Measurement principlesDiode laser spectroscopy (TDLS)
Length of measuring pathCross-duct version 0.5 m ... 6 m (Depending on application)
Open measuring probe (GMP)0.25 m ... 1.5 m (Depending on application)
Gas-testable measuring probe (GPP) 0.227 m ... 0.977 m (Depending on application)
Measuring ranges NH3 0 ... 25 ppm / 0 ... 4,000 ppm NH3 0 ... 25 ppm / 0 ... 100 ppm HF 0 ... 5 ppm / 0 ... 2,000 ppm HCl 0 ... 10 ppm / 0 ... 3,000 ppm Measuring ranges refer to 1 m measuring path Measuring ranges depend on application and device version
Dual measuring ranges: HCl / H2O: 0 ... 10 ppm / 0 ... 3,000 ppm (HCl) 0 ... 50 Vol.-% / 0 ... 100 Vol.-% (H2O) NH3 / H2O: 0 ... 25 ppm / 0 ... 4,000 ppm (NH3) 0 ... 20 Vol.-% / 0 ... 20 Vol.-% (H2O) NH3 / H2O: 0 ... 25 ppm / 0 ... 100 ppm (NH3) 0 ... 40 Vol.-% / 0 ... 40 Vol.-% (H2O) Measuring ranges refer to 1 m measuring path Measuring ranges depend on application and device version Certified measuring ranges HF 0 ... 5 mg/m³ / 0 ... 25 mg/m³ Suitability-tested in the cross-duct type
Response time (t90)1 s ... 360 s
Adjustable AccuracyZero point ≤ ± 2 % Relative to measuring range end value
Sensitivity≤ ± 2 % Within the maintenance interval (6 months), relative to measuring range full scale
Process temperature–40 °C ... +430 °C Depending on device version
Ambient temperature–40 °C ... +50 °C Depends on parameterization, temperature change max. ±10 °C/h
Storage temperature–40 °C ... +55 °C
Ambient humidity≤ 85 % Relative humidity, non-condensing
ConformitiesOnly for HF. Approved for plants requiring approval 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27.BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181
Electrical safetyCE
Enclosure ratingIP65
Test functionsAutomatic check cycle for zero and span point (only for NH3 and HCl)