MCS100FT Multi gas analyser
Extractive FTIR based multi-gas analyser
The FTIR measuring principle allows the simultaneous determination of more than 12 measuring components – tailor-made for the particular requirements of the customer. The MCS100FT FTIR analyser system with its heated measuring cell enables the monitoring of hydrogen fluoride limits as requested by legislation. The MCS100FT is equipped with an oxygen sensor as standard and can be supplemented with a total hydrocarbon analyser. With its reliable measuring technology, its easy operation and low maintenance requirements, the MCS100FT provides a solution that offers unequalled opportunities.
Measured values | CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2, NOx, C3H8, C2H6 |
Performance-tested measurements | CH4, CO, CO2, Corg, HCl, HF, H2O, NH3, NO, NO2, N2O, O2, SO2 |
Measurement principle | FTIR spectroscopy, flame ionisation detection, Zirconium dioxide sensor |
Gas flow rate | ≤ 300 l/h |
Measuring ranges | CH4 0 ... 70 ppm / 0 ... 210 ppm CO 0 ... 60 ppm / 0 ... 1,200 ppm CO2 0 ... 25 Vol.-% Corg 0 ... 7.5 ppm / 0 ... 75 ppm HCl 0 ... 10 ppm / 0 ... 100 ppm HF 0 ... 3 ppm / 0 ... 10 ppm H2O 0 ... 40 Vol.-% NH3 0 ... 13 ppm / 0 ... 65 ppm NO 0 ... 150 ppm / 0 ... 1,500 ppm NO2 0 ... 25 ppm / 0 ... 250 ppm N2O 0 ... 25 ppm / 0 ... 250 ppm O2 0 ... 21 Vol.-% SO2 0 ... 25 ppm / 0 ... 525 ppm NOx 0 ... 100 ppm / 0 ... 1,000 ppm C3H8 0 ... 25 ppm C2H6 0 ... 40 ppm Other measuring ranges and components on request Certified measuring ranges CH4 0 ... 50 mg/m³ / 0 ... 150 mg/m³ CO 0 ... 75 mg/m³ / 0 ... 300 mg/m³ / 0 ... 1,500 mg/m³ CO2 0 ... 25 Vol.-% Corg 0 ... 15 mg/m³ / 0 ... 50 mg/m³ / 0 ... 150 mg/m³ / 0 ... 500 mg/m³ HCl 0 ... 15 mg/m³ / 0 ... 90 mg/m³ / 0 ... 150 mg/m³ HF 0 ... 3 mg/m³ / 0 ... 10 mg/m³ H2O 0 ... 40 Vol.-% NH3 0 ... 10 mg/m³ / 0 ... 50 mg/m³ NO 0 ... 200 mg/m³ / 0 ... 400 mg/m³ / 0 ... 2,000 mg/m³ NO2 0 ... 100 mg/m³ / 0 ... 500 mg/m³ N2O 0 ... 50 mg/m³ / 0 ... 500 mg/m³ O2 0 ... 21 Vol.-% SO2 0 ... 75 mg/m³ / 0 ... 300 mg/m³ / 0 ... 1,500 mg/m³ |
Response time (t90) | ≤ 200 s FID ≤ 45 s |
Sensitivity drift | < 3 %: of the measuring range full scale value per maintenance interval FID < 2 %: of measuring range full scale per week |
Zero point drift | < 3 %: of the measuring range full scale value per maintenance interval FID < 2 %: of measuring range full scale per week |
Detection limit | < 2 %: of measuring range full scale |
Process temperature | ≤ +1,300 °C Sample gas temperature: ≤ +220 °C |
Process pressure | 900 hPa ... 1,100 hPa |
Ambient temperature | +5 °C ... +35 °C, With cooling device +5 °C ... +50 °C |
Storage temperature | –20 °C ... +60 °C |
Ambient pressure | 900 hPa ... 1,100 hPa |
Ambient humidity | ≤ 80 % Non-condensing |
Conformities-Approved for plants requiring approval | 2001/80/EC (13. BImSchV) 2000/76/EC (17. BImSchV) 27.BImSchV TA-Luft (Prevention of Air Pollution) EN 15267 EN 14181 MCERTS |
Electrical safety | CE |
Enclosure rating | IP43, Optional IP54 |